{"product_id":"1x-44-2-ludlum-equivalent-shorter-gamma-scintillation-probe-guaranteed-for-1-yr","title":"1x 44-2 Ludlum Equivalent Shorter Gamma Scintillation Probe GUARANTEED for 1 yr","description":"\u003cdiv class=\"item-specifics\"\u003e\u003cdiv class=\"specs-grid\"\u003e\n\u003cdiv class=\"spec-pair\"\u003e\n\u003cdiv class=\"spec-name\"\u003eBrand\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eLudlum\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-pair\"\u003e\n\u003cdiv class=\"spec-name\"\u003eUnit Type\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eUnit\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-pair\"\u003e\n\u003cdiv class=\"spec-name\"\u003eCustom Bundle\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eNo\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-pair\"\u003e\n\u003cdiv class=\"spec-name\"\u003eModel\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e44-2\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-pair\"\u003e\n\u003cdiv class=\"spec-name\"\u003eMPN\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e47-1532\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-pair\"\u003e\n\u003cdiv class=\"spec-name\"\u003eUnit Quantity\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003e1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-pair\"\u003e\n\u003cdiv class=\"spec-name\"\u003eModified Item\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eNo\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-pair\"\u003e\n\u003cdiv class=\"spec-name\"\u003eCountry of Origin\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eUnited States\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"spec-pair\"\u003e\n\u003cdiv class=\"spec-name\"\u003eRadiation Detector Type\u003c\/div\u003e\n\u003cdiv class=\"spec-value\"\u003eScintillation Detector\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003cdiv class=\"item-description\"\u003e\u003cdiv class=\"description-text\"\u003e\n\u003cp dir=\"ltr\" style=\"margin-top:0; margin-bottom:0;\"\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"572\" data-end=\"618\"\u003e44-2 Equivalent Gamma Scintillation Probe\u003c\/h2\u003e\n\u003ch3 data-start=\"232\" data-end=\"262\"\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"619\" data-end=\"689\"\u003eProfessionally Rebuilt • Performance Documented • One Year Guarantee\u003c\/p\u003e\n\u003cp data-start=\"691\" data-end=\"866\"\u003eListing Includes:\u003cbr data-start=\"708\" data-end=\"711\"\u003e\n• 1x Professionally Rebuilt 1 inch x 1 inch NaI Gamma Scintillation Probe\u003cbr data-start=\"784\" data-end=\"787\"\u003e\n• Compact form factor, approximately 1 inch shorter than standard Ludlum 44-2\u003c\/p\u003e\n\u003chr data-start=\"868\" data-end=\"871\"\u003e\n\u003ch3 data-start=\"873\" data-end=\"927\"\u003eProfessionally Rebuilt to Professional Standards\u003c\/h3\u003e\n\u003ch3 data-start=\"232\" data-end=\"262\"\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"929\" data-end=\"1092\"\u003eEach probe is completely rebuilt prior to sale using an original OEM \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003eLudlum Measurements, Inc.\u003c\/span\u003e housing and professionally selected internal components.\u003c\/p\u003e\n\u003cp data-start=\"1094\" data-end=\"1114\"\u003eEvery unit includes:\u003c\/p\u003e\n\u003cp data-start=\"1116\" data-end=\"1339\"\u003e✔ Brand new 1 inch x 1 inch NaI scintillation crystal\u003cbr data-start=\"1169\" data-end=\"1172\"\u003e\n✔ Matched and tested photomultiplier tube\u003cbr data-start=\"1213\" data-end=\"1216\"\u003e\n✔ Fully rebuilt internal assembly\u003cbr data-start=\"1249\" data-end=\"1252\"\u003e\n✔ Compact overall length with identical detection geometry\u003cbr data-start=\"1310\" data-end=\"1313\"\u003e\n✔ Standard C-Type connector\u003c\/p\u003e\n\u003cp data-start=\"1341\" data-end=\"1496\"\u003eThese are not surplus pulls or unverified detectors. Each probe is stripped, rebuilt, configured, and tested to meet professional survey and laboratory expectations.\u003c\/p\u003e\n\u003chr data-start=\"1498\" data-end=\"1501\"\u003e\n\u003ch3 data-start=\"1503\" data-end=\"1558\"\u003ePerformance Verification \u0026amp; Documentation Included\u003c\/h3\u003e\n\u003ch3 data-start=\"232\" data-end=\"262\"\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"1560\" data-end=\"1647\"\u003eEach probe is plateaued in 25V increments from 300V to 1500V using a calibrated scaler.\u003c\/p\u003e\n\u003cp data-start=\"1649\" data-end=\"1670\"\u003eTesting is performed:\u003c\/p\u003e\n\u003cp data-start=\"1672\" data-end=\"1735\"\u003e• Against background radiation\u003cbr data-start=\"1702\" data-end=\"1705\"\u003e\n• With a Cs reference source\u003c\/p\u003e\n\u003cp data-start=\"1737\" data-end=\"1942\"\u003eFrom this data, the knee of the plateau is identified and verified for stable response. The recommended operating voltage is selected in accordance with Ludlum guidance and is clearly labeled on the probe.\u003c\/p\u003e\n\u003cp data-start=\"1944\" data-end=\"2012\"\u003eThe following are documented and included with your individual unit:\u003c\/p\u003e\n\u003cp data-start=\"2014\" data-end=\"2138\"\u003e• Full HV response data\u003cbr data-start=\"2037\" data-end=\"2040\"\u003e\n• Plateau curve identification\u003cbr data-start=\"2070\" data-end=\"2073\"\u003e\n• Verified operating voltage\u003cbr data-start=\"2101\" data-end=\"2104\"\u003e\n• Stable count rate confirmation\u003c\/p\u003e\n\u003cp data-start=\"2140\" data-end=\"2231\"\u003eEach probe includes a multi-page performance report specific to the exact unit you receive.\u003c\/p\u003e\n\u003chr data-start=\"2233\" data-end=\"2236\"\u003e\n\u003ch3 data-start=\"2238\" data-end=\"2261\"\u003eDetector Overview\u003c\/h3\u003e\n\u003ch3 data-start=\"232\" data-end=\"262\"\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"2263\" data-end=\"2443\"\u003eThis probe delivers performance equivalent to a Ludlum 44-2. It is utilizing a 1 inch x 1 inch NaI scintillation detector coupled to a photomultiplier tube for efficient gamma detection.\u003c\/p\u003e\n\u003cp data-start=\"2445\" data-end=\"2486\"\u003eCommon professional applications include:\u003c\/p\u003e\n\u003cp data-start=\"2488\" data-end=\"2615\"\u003e• Surface contamination surveys\u003cbr data-start=\"2519\" data-end=\"2522\"\u003e\n• Clearance monitoring\u003cbr data-start=\"2544\" data-end=\"2547\"\u003e\n• Laboratory gamma counting\u003cbr data-start=\"2574\" data-end=\"2577\"\u003e\n• Environmental radiation monitoring\u003c\/p\u003e\n\u003cp data-start=\"2617\" data-end=\"2663\"\u003eFully compatible with Ludlum meters including:\u003c\/p\u003e\n\u003cp data-start=\"2665\" data-end=\"2747\"\u003e• Ludlum Model 3\u003cbr data-start=\"2681\" data-end=\"2684\"\u003e\n• Ludlum Model 12\u003cbr data-start=\"2701\" data-end=\"2704\"\u003e\n• Ludlum Model 2241\u003cbr data-start=\"2723\" data-end=\"2726\"\u003e\n• Ludlum Model 2221\u003c\/p\u003e\n\u003cp data-start=\"2749\" data-end=\"2825\"\u003eAnd other compatible instruments configured for NaI scintillation detectors.\u003c\/p\u003e\n\u003cp data-start=\"2827\" data-end=\"2975\"\u003eIf purchased with a meter, one connecting cable per meter is included at no charge and the meter will be configured for proper count rate operation.\u003c\/p\u003e\n\u003cp data-start=\"2977\" data-end=\"3047\"\u003eCables are otherwise sold separately. Please inquire for availability.\u003c\/p\u003e\n\u003chr data-start=\"3049\" data-end=\"3052\"\u003e\n\u003ch3 data-start=\"3054\" data-end=\"3081\"\u003eConstruction \u0026amp; Finish\u003c\/h3\u003e\n\u003ch3 data-start=\"232\" data-end=\"262\"\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"3083\" data-end=\"3105\"\u003eEach probe housing is:\u003c\/p\u003e\n\u003cp data-start=\"3107\" data-end=\"3240\"\u003e• Fully stripped\u003cbr data-start=\"3123\" data-end=\"3126\"\u003e\n• Media blasted\u003cbr data-start=\"3141\" data-end=\"3144\"\u003e\n• Finished with baked-on Cerakote ceramic coating\u003cbr data-start=\"3193\" data-end=\"3196\"\u003e\n• Reassembled with new internal components\u003c\/p\u003e\n\u003cp data-start=\"3242\" data-end=\"3294\"\u003eThese are complete rebuilds, not cosmetic touch-ups.\u003c\/p\u003e\n\u003chr data-start=\"3296\" data-end=\"3299\"\u003e\n\u003ch3 data-start=\"1344\" data-end=\"1374\"\u003eMechanical Revision Notice\u003c\/h3\u003e\n\u003ch3 data-start=\"3301\" data-end=\"3335\"\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"1376\" data-end=\"1611\"\u003eLudlum has produced multiple mechanical revisions of this probe housing over time. Minor differences in cap style, body length, or connector mounting may exist between units. These variations do not affect compatibility or performance.\u003c\/p\u003e\n\u003cp data-start=\"1613\" data-end=\"1695\"\u003eIf matching external configuration is critical, please contact us before ordering.\u003c\/p\u003e\n\u003ch3 data-start=\"232\" data-end=\"262\"\u003e\n\u003chr data-start=\"3564\" data-end=\"3567\"\u003e\n\u003c\/h3\u003e\n\u003ch3 data-start=\"3569\" data-end=\"3606\"\u003eWarranty \u0026amp; Professional Support\u003c\/h3\u003e\n\u003ch3 data-start=\"232\" data-end=\"262\"\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"3608\" data-end=\"3703\"\u003eEach probe is guaranteed to be fully functional and free of defects for one year from delivery.\u003c\/p\u003e\n\u003cp data-start=\"3705\" data-end=\"3729\"\u003eWarranty does not cover:\u003c\/p\u003e\n\u003cp data-start=\"3731\" data-end=\"3846\"\u003e• Physical damage\u003cbr data-start=\"3748\" data-end=\"3751\"\u003e\n• Abuse or mishandling\u003cbr data-start=\"3773\" data-end=\"3776\"\u003e\n• Damage to the scintillator or photomultiplier tube due to dropping\u003c\/p\u003e\n\u003cp data-start=\"3848\" data-end=\"3922\"\u003eThese are precision radiation detectors and should be handled accordingly.\u003c\/p\u003e\n\u003cp data-start=\"3924\" data-end=\"3964\"\u003eRepair services are available if needed.\u003c\/p\u003e\n\u003chr data-start=\"3966\" data-end=\"3969\"\u003e\n\u003ch3 data-start=\"3971\" data-end=\"3999\"\u003eAdditional Information\u003c\/h3\u003e\n\u003ch3 data-start=\"232\" data-end=\"262\"\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"4001\" data-end=\"4327\"\u003e• Listing is for ONE custom built and tested probe\u003cbr data-start=\"4046\" data-end=\"4049\"\u003e\n• Cables not included unless purchased with a meter\u003cbr data-start=\"4100\" data-end=\"4103\"\u003e\n• Multi-unit pricing available\u003cbr data-start=\"4133\" data-end=\"4136\"\u003e\n• Signature may be required upon delivery\u003cbr data-start=\"4177\" data-end=\"4180\"\u003e\n• Licensed, traceable calibration services available upon request for an additional fee\u003cbr data-start=\"4267\" data-end=\"4270\"\u003e\n• International buyers please message prior to purchase\u003c\/p\u003e\n\u003cp data-start=\"4329\" data-end=\"4445\"\u003e📩 Questions about bundles, calibration, cosmetic restoration, or bulk orders?\u003cbr data-start=\"4407\" data-end=\"4410\"\u003e\nContact us. We are happy to assist.\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003cstyle\u003e\n  .item-specifics, .item-description {font-family: Arial, sans-serif; font-size: 14px; margin-top: 16px;}\n  .title {font-size: 16px; font-weight: bold; margin: 0 0 8px 0;}\n  .specs-grid {display: grid; grid-template-columns: repeat(2, 1fr); gap: 12px 24px;}\n  .spec-pair {display: grid; grid-template-columns: 120px 1fr; gap: 8px;}\n  .spec-name {font-weight: bold; color: #111;}\n  .spec-value {color: #333;}\n  .description-text {margin-top: 8px; line-height: 1.4; color: #333;}\n\u003c\/style\u003e\n","brand":"Tech By MBF","offers":[{"title":"Default Title","offer_id":50664258863351,"sku":"v1|277772592117|0","price":850.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0925\/3752\/0375\/files\/s-l1600_8dba0f26-b018-4124-821c-4529d5217d30.jpg?v=1781046431","url":"https:\/\/techbymbf.com\/products\/1x-44-2-ludlum-equivalent-shorter-gamma-scintillation-probe-guaranteed-for-1-yr","provider":"Tech By MBF","version":"1.0","type":"link"}